Ovens & Boilers
Components for sample conditioning systems of extractive gas analyzers
JCT ANALYSENTECHNIK GMBH – the expert partner for monitoring process gases and stack emissions
With a worldwide presence in multiple industries through gas sample conditioning solutions and products for extractive analysis: Power Generation, Pharmaceutical, Chemical, Biogas, Metal & Steel, Cement, Pulp & Paper, Waste Incinerators, among others. With versions of components for Safe Area or for areas classified as dangerous.
JES-301L / JES-301 / JES-301V / JES-301E1 / JES-301E1SV / JES-360 / JES-360H / JES-360Ex / JES-370 / JES-380 gas sampling probes that guarantee a continuous sample and representative in processes containing dust and humidity, without condensation or chemical reactions of the sample gas, with convenient filter replacement and low maintenance, which ensures reliable protection of the analyzer system with easy commissioning.
JER-EH / JH3BE / JH3E & JH3ER / JH3F & JH3FR / JH3FG & JH3FGR / JH3BEX / JH3EX gas sample transfer from the sampling point to the analyzer system, with electrically traced sample lines, which guarantee to be in good condition safe above acid dew point, for indoor and outdoor use, no condensate formation, no freezing:
Sample gas cooler (compressor) JCS-100 / JCT-1 & JCT-2 / JCT-3 / JCT-5 Ex / JCT-2 Ex for continuous drying of sample gas to a constant outlet dew point and Accurate, that minimizes cross-sensitivities to water vapor and volumetric errors in extractive gas analysis and/or in emissions and process monitoring. It uses proven and reliable technology, with various heat exchanger materials, in one or two independent gas paths. Handles high flow rates and steam dew points, making continuous removal of condensate in a low maintenance operation.
Sample Gas Cooler (Peltier) JCM-320 / JCM-300 / JCM-310 /JCMF-310 for continuous drying of sample gas to a constant and accurate outlet dew point, minimizing cross sensitivities to steam water and volumetric errors in the analysis of extractive gases and/or in the monitoring of emissions and processes. Its most notable advantages:
Condensate treatment that includes accessories and components such as KW-2 condensate detector, JCM-3PC pre-cooler unit, JSR-25 condensate dosing pump, 11-LD automatic liquid drainer, JPCS condensate pre-separator, container for JKS-10 condensate.
JF-1 sample gas filters reliably and continuously remove dust and contamination from the sample for analyzer protection, without disturbing the gas sample. They are easy to assemble and integrate into gas analysis systems, with long-life filtration elements, resistant to corrosion and gas-tight, with low and easy maintenance effort.
JSF-1 / JSF-2 acid filters, remove aerosols (liquid particles) from the gas sample even at high pressures, to protect analyzers, reliably and continuously, without altering the gas sample. They are easy to assemble and integrate into gas analysis systems, with long-life filter elements with upstream dust filtration, and are corrosion-resistant and gas-tight, with low and easy maintenance effort.
Liquid Stop JAF-1 to reliably prevent the penetration of liquids into the analyzer, made of semi-permeable membrane with fluorine polymer coating, with a fine filter of 0.1 µm. Gas flow is stopped with a completely wet membrane.
JBF-301L Heated Sample Gas Filter for hot dust filtration of gas sample without disturbing the sample or requiring a temperature controller. Use ceramic filter elements, 2 µm porosity or 0.2 µm with pyrex wool.
Gas sample pumps JSP-86 / JSP-86 KTE / JSP-89 compact and/or Explosion Proof type (for installation in ex-Zone 1 or 2), with high suction power, low noise and vibration operation. Corrosion resistant construction (EPDM, Ryton®, Viton®, PTFE coated), maintenance free, gas tight and long life. Capacities of 3, 5.5 and 9.5 Nl/min. Suitable fittings, mounting clamp and vibration absorbers are supplied as accessories.
NO2 to NO converter for NOx measurement JNOX to enable use of infrared analyzers. High conversion rate with long cartridge life of approx. 10^6 ppmh and efficiencies >96%; heated bypass option for additional measurements or faster response times.
Gas conditioning systems JCL-301, JCL304 / JCL-319, JCC-R / JCC-Q / JCC-P / JCC-L for stationary or mobile extractive analysis in emission or process monitoring, of wet process gases. Continuous drying of sample gas to a constant and accurate outlet dewpoint (even at variable loads) minimizing water vapor cross-sensitivities and volumetric errors, with continuous condensate removal and fast response time due to low volume dead.
It is a complete solution for a large number of applications, with sustainable reproducible measurement results that offers optimal operational safety thanks to self-monitoring while being low-maintenance with a service-friendly design.
It offers 4 enclosure versions: 19” rack mount, rear panel mount, side panel mount, and portable version. Version for independent sample gas paths 1 to 4 with speed-controlled fan and status LEDs with event memory. Additional Acid Dosing Pump and RS 485 Interface options.
Other features:
- Basic device with high-performance compressor sample gas cooler
- Integrated condensate pumps
- Digital temperature display and status LED
- Status contact
Additional options:
- Corrosion-resistant, high-performance sample gas pump with safety interlock.
- Robust and easy-to-maintain fine dust filter or disposable filter
- Corrosion resistant flowmeter with precise needle valve
- Reliable condensate monitoring
Gas analyzers:
JFID-ES Portable NMHC Analyzer for non-methane hydrocarbons with dual detector for continuous real-time measurement of NMHC, THC or Methane CH4, fast response time, low maintenance, independent of pressure fluctuations, accurate and reliable, with adjustable ranges , relays for alarms, events and diagnostics.
It uses the proven Flame Ionization technology and simultaneously monitors NMHC and CH4, indicating the values of these two concentrations in ppm or mg/m3 on the display.
JFID TOC Total Hydrocarbon Analyzer for TOC in steam and condensates / JFID-ES THC/VOC / JFID-FE / JFID-MK for continuous analysis of THC/VOC in emissions monitoring, LEL safety monitoring, Scrubber efficiency, analysis process gases, leak detection, solvent recovery, carbon absorbers, control of the coating process.
- No sample conditioning is required
- Measuring head connected directly to a DIN connection
- Fast analysis results: Response time <1 sec.
- Low maintenance
- Maintenance-free pump system
- Independent of pressure fluctuation
It uses the proven flame ionization technology, for safe zone or Ex zone 1 or 2; automatic calibration with span check. Simultaneous display in ppm or mg/m3.
Thermal Conductivity Analyzer FTC300 / Conthos3-TCD for accurate and long-term stable extractive analysis in quality and process monitoring of the concentration of simple gas components such as H2, CO2, O2, He, Ar, CH4, N2, NH3, CO, SF6 in binary gas mixtures in the gas industry, food, insulating glass and heat treatment.
- High sensitivity, e.g. Ex. 0 …. 0.5 Vol.% H2 in N2; noise <10 ppm H2 in N2 with durable measuring cell
- Sequential measurement of 15 binary gas mixtures due to multi-gas mode
- It is possible to compensate for the cross-sensitivity of an interfering component
- Fast response time (T90 <1 s)
- Comfortable menu and operator navigation during calibration and parameterization
- Classic two-point calibration or one-point calibration
- RS232 access to all data and (measurement) parameters
Gas Analyzer by Thermal Conductivity for ATEX zone 1 and 2 model Conthos3-TCD Ex applicable in:
- Gases from metallurgical processes such as blast furnaces with flammable gases in hazardous áreas
- Steel industry: heat treatment and hardening
- Petrochemical: Flammable gases in hazardous areas – Synthesis gas processing / gas reformer and coal gasification
- Monitoring of gas purity, pressure swing adsorption and LEL/UEL
- Purity of H2 and O2 in the electrolysis of wáter
- Hydrogen monitoring in turbogenerators
Dirección: Ave. Cra 19 No. 125-65 Ofc 402
Teléfono: +57 (601) 730 1906
Cel: +57 3175320042
comercial@sinduly.com